- NEC P400 and 600
-
- NOTES: These are quad NAM handheld units.
- The ESN prefix is 135 decimal & 87 hex.
- An NEC programing adaptor and converter cable must be used to
- program these units.
- NEC: 1-800-421-2141
-
- NAM programing:
-
- 1. With the power off connect the NEC programing adaptor and cable.
-
- 2. Turn power on.
-
- 3. Press RCL # 0 1 to enter test mode.
-
- 3. Press RCL # 7 1 to enter programing mode.
-
- 4. Press # to increment and store each step.
-
- 5. At any time press and hold CLR to return to test mode, press RCL # 0 2
- to complete and exit programing.
-
-
-
- PROGRAMING DATA
-
- STEP# #OF DIGITS/RANGE DISPLAY DESCRIPTION
-
- 01 10 DIGITS Phone No. MIN (AREA CODE & TEL#)
- 02 4 DIGITS Lock Code LOCK CODE
- 03 00000 - 32767 Home Area SYSTEM ID
- 04 2 DIGITS G.I. Mark GROUP ID (10 IN USA)
- 05 0333 OR 0334 First P-CH INITIAL PAGING CHANNEL
- 06 0 OR 1 Sys Select PREFERRED SYSTEM (0=B, 1=A)
- 07 2 DIGITS ACCOLC ACCESS OVERLOAD CLASS
- 08 0 OR 1 MIM Mark MIN MARK
- 09 0 OR 1 Local Use LOCAL USE MARK
- 10 3 DIGITS EMG No EMERGENCY NUMBER (911)
-
- LOCK & UNLOCK: F # four digit code.
-
- SYSTEM SELECT:
- P400: F 5 then 5 to scroll, CLR to store.
- P600: F 5 4 then RCL to scroll, CLR to store.